IPL Systems Australia

 

RF   [Radio Frequency] 

Body Shaping Systems

 

  

Certificates:    

 

ISO 9001:2001

ISO 13485:2003

European Medical CE

Chinese FDA CE

 

 

 

     

RF 01                         $ 28,000.00

 
Specifications:
Voltage: 220V/110V, 60Hz/50Hz.
RF frequency: 0-10 MHZ
RF energy : 20-150J/cm2
Output model: mono-polar, or bipolar
Output control mode: Foot switch, Handle Switch,
Material for head tube: leather
Screen: 12.4 inches real color touching screen
Cooling manner: water+wind+semi-conductor+cooling gel
Temperature of probe: -10 oC-0 oC
IC card.
Output power: 1200w
Size: 35 x 35 x 110 cm
Weight: 50Kg

 


 

 

 

RF 02                         $ 27,000.00

 

Specifications:

Voltage: 220V/110V, 60Hz/50Hz.
RF frequency: 0-10 MHZ
RF energy : 20-150J/cm2
Output model: mono-polar, or bipolar
Output control mode: Foot switch, Handle Switch,
Material for head tube: leather
Cooling manner: water+wind+semi-conductor+cooling gel
Temperature of probe: -10 oC-0 oC
Screen: 12.4 inches real color touching screen
IC card.
Output power: 1200w
Size: 35 x 40 x 110 cm
Weight: 50Kg

 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF 05         $ 26,000.00 
 


Specifications:

Voltage: 220V/110V, 60Hz/50Hz.
RF frequency: 0-10 MHZ
RF energy : 20-150J/cm2
Output model: mono-polar,or bipolar
Output control mode: Foot switch, Handle Switch,
Cooling manner: water+wind+semi-conductor+cooling gel
Temperature of probe: -10 oC-0 oC
Output power: 900w
Size: 58x49x110cm
Weight: 45Kg

 


 

              

 

Before RF Treatment                     After RF Treatment

 

Treatment Theory  Bi-polar

 

RF beauty equipment is the high-tech beauty equipment, great safety and no wound.

   The collagen is the main structure of skin. However, the collagen and elastin will reduce and lack because of sun oxidation and air pollution as the time flies ,. As sustainment of skin, flexibility fibre and collagen fibre would gradually lose elasticity and tensility. Sagging skin, or other visible signs of aging will appear.

      The RF equipment has the cooling system of surface layer, and uses proprietary technology to deliver radiofrequency energy to the deep layers of the skin and its underlying tissue. The heat will accelerate the blood circle, lets the fibre structure shrink instantaneously, and stimulates the renewal of collagen. In response, the collagen shrinks and remodels over time, providing you with tighter skin, renewed facial contours.

 

Application:

 

1.     Face lifting

2.     Skin lifting around eyes

3.     Skin lifting on neck

4.     Improve conditions of sagging skin

5.     Forehead wrinkle removal

6.     Breast lifting

7.     Shape back contour

8.     Shape belly contour

9.     Shape buttocks and legs contour

10.   Hand care, effective on removal whelk and scars

 

 

 

         

 

    

Before RF Treatment                      After RF Treatment

 

Teatment Theory Uni Polar

 

Lipolysis treatment

 

Influenced by a high frequent electromagnetic field of mono RF, water molecule in human body are wagging and shaking with high speed, as a result, heat can be produced by the friction between water. Passing through body impedance , the electricity produce heat and the highest temperature occurs several millimeters under dermis with no harm.

 

This newly deposited connective tissue matrix may be used to strengthen the natural fibrous layer between the dermis and subcutaneous tissue. Adipose tissue is highly sensitive to blood flow. The thermally-induced hyperemia caused by the Unipolar RF field increases blood flow and the release of free fatty acids (FFA) to a local adipose tissue bed and may increase lipolysis stimulating catecholamines available in the local area, thus promoting release of FFA into the bloodstream. Because of the thermal trauma to the fat cells, triglycerides may be released from the fat cells. These triglycerides are likely broken down into free fatty acids and glycerol by the enzyme lipoprotein lipase (LPL). The free fatty acids (water insoluble) bind to albumin and are slowly transported to the liver. Glycerol (water soluble) is transported to the liver via the interstitial fluid compartments tissue fluids and blood fluid.

 

Cellulite treatment

 

1) stimulate fibroblast and new collagen growth

2) stimulate the blood circulation and fat drainage to lymph system .

3) the decompose of fatty acid and thermal effect contribute the death of the lipocyte.

The deeper RF field of the Unipolar causes tightening of the fibrous layer of tissue at the interface between the dermis and the subcutaneous tissue, thus promoting reduction in cellulite symptoms. Controlled thermal injury may result in tissue shrinkage followed by an inflammatory response accompanied by the migration of fibroblasts into the area. The intentional and directed infiltration of fibroblasts to the thin layer of tissue, including the interface, may be used to reinforce its structural integrity, resulting in amelioration or elimination of the subdermal fat protrusion that causes skin bulging. The area is reinforced with additional connective tissue deposits as part of the tissue repair and healing phase. This phase is followed by a period of maturation of the newly deposited connective tissue, thereby resulting in contracture and tightening of the injured tissues and the tissue overlying the dermis-epidermis interface.

 

 

 

 

           

 

 Before RF Treatment                    After RF Treatment

 

 

Characters of RF

 

1.     Collagen renewal: the RF energy could be reached the deep layers of skin, stimulating the collagen structure to renew. In response, the best result of tighter skin, renewed facial contours can be expected.

2.     Large color touch-screen (8.4inch), simple operation.

3.     Instantaneous shrinking skin: when the temperature of collagen up to 45o-60o, the collagen will shrink instantaneously. Therefore, one time treatment could let u feel the best result.

4.     Long renewal effect: after half year’s treatment, the renewal of collagen makes your skin activated. 

5.     Great safety: surface layer cooling makes the RF energy and its released speed could be controlled so as to make great safety during the treatment.

6.     Comfortable: non-invasive radiofrequency technology, no blood, wound, or lay off.

7.     Long effect: one time treatment can make you feel the best result, and last for 3-5 years.

8 .  Treatment extensive: it could be applied to anyone’s sagging skin and aging skin.

 

 

 

Difference between bipolar and unipolar:

 

Bipolar RF is mainly used to skin rejuvenation whereas unipolar RF is mainly used for fat reduction.

 

 

Back to IPL Systems

 